4-44
Check the UV illumination intensity
1
Mount the sensor part of the illumination meter on the illumination
meter bracket.
(1) Turn over the illumination meter bracket and insert the sensor into the guide part.
Set it with the sensor hole faces downward so that the hole can be seen from the
obverse side of the bracket.
(2) Insert the code between guides and then slide the sensor to the code side.
Be sure to press the sensor part. Do not pull the code.
(3) Turn the bracket to the obverse side and adjust the sensor hole to the center of the bracket
hole.
2
Select “UV lamp mode” from the maintenance menu.
(1) Press the key in the local mode.
(2) Press the to select [MAINTENANCE] and press the key.
(3) Press the to select [UV LAMP] and press the key.
(4) Press the to select [LEVEL CHECK] and press the key.
(5) Press the key.
The head wiping will be performed.
(6) Press the key.
The carriage will move to the left rear part.
FUNCTION
ENTER
ENTER
ENTER
LEVEL CHECK
WI PE START : en t
ENTER
LEVEL CHECK
HEAD MOVE : e n t