Replacing UV lamp
4-40
Resetting UV lamp irradiation duration
After replacing the UV lamp, reset the irradiation duration stored in this unit.
1
Select the “UV LAMP MODE” of the maintenance menu.
(1) Press the key in the local mode.
(2) Select the [MAINTENANCE] by pressing the or key, and press the key.
(3) Select the [UV LAMP] by pressing the or key.
(4) Press the key.
2
Select [LAMP TIMER] by pressing the
or key.
3
Press the key.
4
Select a UV lamp to be reset by
pressing the or key.
CH1, CH2, ALL(Reset irradiation duration of both UV lamps)
5
Press the key twice.
Reset irradiation duration.
A message shown in the right is displayed when
resetting is completed.
6
Press the key twice to finish.